cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Ambient Temperature Sensor / Switch HVAC > < All Technical Service Bulletins for Air Duct:|631104
Page 2
background image

Install an additional heater duct, P/N 25646109, that directs air toward the driver's foot and increases air flow. This duct is installed to the left side of the
air distributor below the mode valve actuator. Figure 1 shows the location point of the template used for cutting the hole for the additional duct. The
template rests on the lower edge of the air distributor where the floor outlet assembly attaches to the air distributor. Figure 2 is the actual size of the
template necessary for installing the duct. The duct is retained to the air distributor with an interference fit and a screw, refer to Figure 3.

Parts Information

Parts are currently available from GMSPO.

Warranty Information

For vehicles repaired under warranty, use:

Labor Operation

Labor Time

D1586

0.4 hr

Ambient Temperature Sensor / Switch HVAC > < All Technical Service Bulletins for Air Duct:|631104