cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

03-01-37-002|Page 8694 > < 03-01-37-002
Page 2
background image

^

Remove the blower motor screws (either 3 or 5 screws).

^

Remove the blower motor from the HVAC Module. 

Installation Procedure

1.

If present, remove the 2 ribs located on the barrier. Refer to Step 3 and the illustrations in the Instruction Sheet, P/N, 52494110, found in the 
blower motor kit.

Important:

Ensure the blower motor gasket makes a complete seal around the blower motor.

2.

Install the new blower motor with heat shield. Refer to Steps 4 and 5 in the Instruction Sheet, P/N 52494110, found in the blower motor kit.

3.

Install the blower motor retaining screws.

Tighten

Tighten the screws to 4 N.m (35 lb in).

4.

Tighten the lower heat shield retaining screws to 4 N.m (35 lb in).

5.

Connect the connector to the blower motor.

6.

Install the solenoid purge valve. 

7.

Reposition and connect the ignition control module assembly. 

8.

Install the cross-car brace.

9.

Connect the negative battery cable.

Eldorado/Seville-HVAC Blower Motor

Caution:

Before servicing any electrical component, the ignition key must be in the OFF or LOCK position and all electrical loads must be OFF, unless
instructed otherwise in these procedures. If a tool or equipment could easily come in contact with a live exposed electrical terminal, also disconnect
the negative battery cable. Failure to follow these precautions may cause personal injury and/or damage to the vehicle or its components.

Removal Procedure

1.

Disconnect the negative battery cable.

2.

Remove the camshaft cover. 

3.

Remove the blower motor.

^

Disconnect connector from the blower motor.

^

Remove the blower motor screws (either 3 or 5 screws).

^

Remove the blower motor from the HVAC Module. 

Installation Procedure

1.

If present, remove the 2 ribs located on the barrier. Refer to Step 3 and the illustrations in the Instruction Sheet, P/N 52494110, found in the 
blower motor kit.

Important:

Ensure the blower motor gasket makes a complete seal around the blower motor.

2.

Install the new blower motor with heat shield. Refer to Steps 4 and 5 in the Instruction Sheet, P/N 52494110, found in the blower motor kit.

3.

Install the blower motor retaining screws.

03-01-37-002|Page 8694 > < 03-01-37-002