cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Refrigerant Oil > < General Description
Page 1
background image

Refrigerant: Service and Repair
Recovery, Recycling, Charging & Adding Oil

If the refrigerant charge is abruptly lost due to a large refrigerant leak, approximately 90 ml (3 fluid ounces) of refrigerant oil will be carried out of the
system suspended in the refrigerant. Any failure that caused an abrupt refrigerant discharge will experience this oil loss. Failures that allow the
refrigerant to seep or bleed off over time do not experience this oil loss.

Upon replacement of a component which caused a large refrigerant leak, add 90 ml (3 fluid ounces) of new polyalkylene glycol (PAG) synthetic 
refrigerant oil (GM P/N 12345923 or equivalent) plus the required amount of oil for the particular component (as outlined above). Add the oil directly to
the replaced component if possible. If the oil cannot easily be added to the replaced part, add the oil to the accumulator.

New oil must be added to the system when components are replaced, as 
follows:

^

Compressor - The compressor requires 240 ml (9 fl oz) of PAG refrigerant oil. Replacement compressors will not have any oil in the
compressor. The correct amount of oil needs to be added to the replacement compressor before installation.

^

Evaporator - Add 90 ml (3 fl oz).

^

Condenser - Add 30 ml (1 fl oz).

^

Accumulator - Add 105 ml (3.5 fl oz).

The accumulator should only be replaced when a physical perforation to the shell is found resulting in a leak, the O-ring seat is damaged, or the
inlet/outlet line fitting threads are damaged, or if the accumulator has been left open.

Refrigerant Oil > < General Description