background image

Powertrain Control Module: Description and Operation
Trip and Warm-Up Cycle

TRIP

Description

The ability for a DTC to run depends largely upon whether or not a Trip has been completed. A Trip for a particular DTC is defined as vehicle
operation, followed by an engine off period and a driving mode such that any particular DTC has had sufficient time to complete testing.

Operation

The requirements for trips vary as they may involve items of an unrelated nature; driving style, length of trip, ambient temperature, etc. Some
DTCs run only once per trip (e.g. catalyst monitor) while others run continuously (e.g. misfire and fuel system monitors). If the proper enabling
conditions are not met during that ignition cycle, the tests may not be complete or the test may not have run.

WARM-UP CYCLE

Description

In addition, the execution of a DTC may also be bound by conditions which must comprehend a Warm-up cycle. A Warm-up cycle consists of
engine start-up and vehicle operation such that the coolant temperature has risen greater than a certain value (typically 40°F) from start-up
temperature and reached a minimum temperature of 160°F. If this condition is not met during the ignition cycle, the DTC may not run.