DeVille V8-4.6L VIN Y (1998)
Suspension Main Relay: Description and Operation
GENERAL DESCRIPTION
This relay is used to switch battery voltage to all four of the damper actuators. The relay is located in the trunk compartment micro relay center #4.
The high-side of the relay coil is connected to battery voltage through a fuse. The low-side of the relay coil is connected to the Damper High-Side
Relay Enable line of the Continuously Variable Road Sensing Suspension (CVRSS) control module.