INSTALLATION PROCEDURE

1. Install the EVAP canister purge solenoid valve (4) to the bracket (3).

2. Install the EVAP canister purge solenoid valve bolt (1).

^

Tighten the bolt to 12 N.m (106 lb. in).

3. Install the solenoid quick-connect fitting at the EVAP canister purge solenoid (2). Refer to Quick Connect Fitting(s) Service (Plastic Collar).

4. Install the solenoid quick-connect fitting from the EVAP canister purge solenoid to the enhanced EVAP service port (5).

5. Install the electrical connector to the EVAP canister purge solenoid (4).

6. Install the intake manifold top cover.

^

Tighten the bolt to 3 N.m (27 lb. in).