cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 8598 > < Diagram Information and Instructions|Page 8596
Page 3
background image

Notice:  Refer to Fastener Notice in Service Precautions.

3. Install the 6 EBCM to BPMV screws (2).

^

Tighten the 6 screws to 3.2 Nm (28 inch lbs.).

4. Install the BPMV pump motor harness pigtail electrical connector (2) to the EBCM (3).

Notice:  To prevent equipment damage, never connect or disconnect the wiring harness connection from the EBCM with the ignition switch in the ON
position.

5. Install the EBCM electrical connector (1) to the EBCM (4).
6. Install the EBCM connector position assurance (2) to the EBCM electrical connector (1).

Diagram Information and Instructions|Page 8598 > < Diagram Information and Instructions|Page 8596