DeVille DHS V8-4.6L VIN Y (2000)
Notice: Refer to Fastener Notice in Service Precautions.
3. Install the 6 EBCM to BPMV screws (2).
^
Tighten the 6 screws to 3.2 Nm (28 inch lbs.).
4. Install the BPMV pump motor harness pigtail electrical connector (2) to the EBCM (3).
Notice: To prevent equipment damage, never connect or disconnect the wiring harness connection from the EBCM with the ignition switch in the ON
position.
5. Install the EBCM electrical connector (1) to the EBCM (4).
6. Install the EBCM connector position assurance (2) to the EBCM electrical connector (1).