DeVille DHS V8-4.6L VIN Y (2000)
4. Disconnect the temperature sensor electrical connector.
5. Remove the evaporator hose fastener (1).
6. Disconnect the evaporator hose assembly (2) from the evaporator core.
7. Remove the upper filler panel.
8. Remove the nut (1) retaining the evaporator hose assembly (3) to the condenser.
Disconnect the evaporator hose assembly (3) from the condenser.
9. Remove the evaporator hose assembly.
INSTALLATION PROCEDURE
TOOLS REQUIRED
J 39400-A Electronic Halogen Leak Detector
IMPORTANT: Inspect the seal washers for damage.
Replace the seal washers that are damaged.
The sealing washers do not require lubrication.
NOTE: Refer to Fastener Notice in Service Precautions.
1. Connect the evaporator hose assembly to the condenser.
Tighten
Tighten the evaporator hose fastener (1) to 20 N.m (15 lb ft).