DeVille DHS V8-4.6L VIN Y (2000)
8. Place the module with the vinyl trim cover facing up and away from the surface on a work bench.
9. Clear a space on the ground about 1.85 M (6 ft) in diameter for deployment of the module. If possible, use a paved, outdoor location free of
activity. Otherwise, use a space free of activity on the shop floor. Make sure you have sufficient ventilation.
10. Make sure no loose or flammable objects are in the area.
11. Place the J 39401-B SIR Deployment Fixture in the center of the cleared area.
12. Fill the fixture plastic reservoir with water or sand.
13. Mount the module (1) in the SIR deployment fixture (3) with the vinyl trim cover facing up using the following mounting method.
IMPORTANT: Securely hand tighten all fasteners prior to deployment.
14. To mount, use two M 6 x 1.0 nuts (2) with washers in order to secure the module (1) to the fixture (3).