1. Install the SDM (2) to console floor (3).

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the SDM mounting fasteners (1).

Tighten
Tighten fasteners to 9 N.m (80 lb in).

3. Connect the SDM wiring harness connector (3) to the SDM (2).
4. Install push-on clip (1) securing SDM wiring harness to console stud.

5. Push down flex lock button (3) and then move sliding connector locking cover (4) to the close position.
6. Install the Connector Position Assurance (CPA) (1) to the inflatable restraint sensing and diagnostic module (SDM) wiring harness connector (2).