DeVille DHS V8-4.6L VIN Y (2000)
1. Install the generator to the engine.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants,
or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may
damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
2. Install the generator bolts (1,2,3).
Tighten the bolts to 50 N.m. (37 lb ft).
3. Connect the following electrical connections to the generator:
-
Regulator
-
Battery output
Tighten the battery output cable to 13 N.m. (115 lb in).
-
Heated windshield (if equipped)