IMPORTANT:  After programming, perform the following to avoid future misdiagnosis:

1. Turn the ignition OFF for 10 seconds.
2. Connect the scan tool to the data link connector.
3. Turn the ignition ON with the engine OFF.
4. Use the scan tool in order to retrieve History DTCs from all modules.
5. Clear all history DTCs.

Body Control Module Programming/RPO Configuration (IPM)

PROCEDURE TO CALIBRATE AN INSTRUMENT PANEL INTEGRATION MODULE (IPM)

Ensure the scan tool has been updated with the latest software version.

The following steps should be followed to perform the recalibration update.
1. Ensure the scan tool has been updated with the latest software version.
2. Connect a scan tool to the Data Link Connector (DLC).
3. The ignition should be ON, but the engine should not be operating.
4. Select Instrument Panel Module.
5. Select Special Functions.
6. Select Miscellaneous Test.
7. Select IPM Recalibration.

The scan tool will recalibrate the IPM with the latest version. To verify the proper version has been installed follow these steps:
1. Select Data Display.
2. Select Module Information.
3. View the calibration ID number. The calibration number must match the version loaded on the scan tool.

IMPORTANT:  After programming, perform the following to avoid future misdiagnosis:

1. Turn the ignition OFF for 10 seconds.
2. Connect the scan tool to the data link connector.
3. Turn the ignition ON with the engine OFF.
4. Use the scan tool in order to retrieve History DTCs from all modules.
5. Clear all history DTCs.

Body Control Module Programming/RPO Configuration (RIM)

PROCEDURE TO SET UP A REAR INTEGRATION MODULE (RIM)

Before replacement record the personalization settings to transfer to the new module, if they are available.

After replacement of the Rear Integration Module, perform the following procedure.
1. Recalibration of the automatic level control.
2. Perform the vehicle personalization to reset the owner's desired personalization settings.

The recalibration procedure follows:
1. Ensure the scan tool has been updated with the latest software version.
2. Connect a scan tool to the Data Link Connector (DLC).
3. Turn ON the ignition, with the engine OFF.
4. Under the Chassis Main Menu, select Rear Integration Module.
5. Under the Rear Integration Module Main Menu, select Recalibration.
6. Follow the scan tool on screen instructions to recalibrate the automatic level control.
7. Perform the vehicle personalization to reset the owner's desired personalization settings. Refer to Personalization Description and Operation in

Personalization.

Set Japan Key Fob Option for Japan Only.
1. Under the Body Main Menu, select Rear Integration Module.
2. Under the Rear Integration Module Main Menu, select Special Functions.
3. Under the Special Functions Menu, select Set Options.
4. Under the Set Options menu, the user selects Japan Key Fob Option.
5. Japan Key Fob Option, to continue with the procedure follow the scan tool on screen instructions to Select the Japan Key Fob Option.
6. Perform the vehicle personalization to reset the owner's desired personalization settings. Refer to Personalization Description and Operation in

Personalization.

IMPORTANT:  After programming, perform the following to avoid future misdiagnosis:

1. Turn the ignition OFF for 10 seconds.
2. Connect the scan tool to the data link connector.
3. Turn the ignition ON with the engine OFF.

Procedures|Page 423 > < Procedures