Ignition Cable: Customer Interest
Heater Blower - Failure After Plug Wire/Module Service

Group Ref.: HVAC
Bulletin No.: 471101A
Date: May, 1994

SUBJECT:
HEATER BLOWER MOTOR FAILURE AFTER SERVICING RIGHT HAND (REAR) BANK SPARK PLUG WIRES, SPARK PLUGS AND/OR 
IGNITION CONTROL MODULE (CHECK SPARK PLUG WIRE ROUTING)

MODELS:
1994 CADILLAC ELDORADO, SEVILLE AND CONCOURS 
WITH 4.6L NORTHSTAR ENGINE (VINs Y, 9 - RPOs LD8, L37)

THIS BULLETIN IS BEING REVISED TO CHANGE THE LABOR OPERATION NUMBER. PLEASE DISCARD BULLETIN 471101.

CONDITION:

Some owners may experience a heater blower motor failure after service to the ignition control module, rear (right) bank spark plug and/or rear (right)
bank spark plug wires have been performed.

CAUSE:

If the spark plug wires are routed incorrectly, laying near or contacting the blower motor housing, voltage discharges from the right (rear) bank spark
plug wires may affect blower motor operation and/or cause the blower motor to fail.

CORRECTION:

If servicing an engine and rear bank spark plug wire removal is necessary, exercise caution when installing spark plug wires. Spark plug wires must be

routed away from the blower motor mounted on the cowl panel. Refer to Corporate Bulletin No. 316005 (Cadillac Bulletin 93T101, GM of Canada
93-6-118) for proper spark plug wire routing artwork and information.

WARRANTY INFORMATION:

For vehicles repaired under warranty, use:

Labor Operation:  T6723

Labor Time:  0.5 Hour