1. Ignition OFF, remove the X80 accessory power receptacle - 110 V AC. 
2. Test for greater than 1 M ohm between terminal 3 and terminal 6. 

‹› If less than the specified range, replace the X80 accessory power receptacle - 110 V AC.

3. Test for less than 3 ohm between the following terminals: 

*

The terminal 3 and the applicable receptacle terminal

*

The terminal 6 and the applicable receptacle terminal

‹› If greater than the specified range, replace the X80 accessory power receptacle - 110 V AC.

4. Test for infinite resistance between terminal 4 and terminal 1. 

‹› If not the specified value, replace the X80 accessory power receptacle - 110 V AC.

5. Connect an AC powered device to the X80 accessory power receptacle - 110 V AC. 
6. Test for less than 3 ohm between terminal 4 and terminal 1. 

‹› If greater than the specified range, replace the X80 accessory power receptacle - 110 V AC.

Repair Instructions

Perform the Diagnostic Repair Verification   (See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Diagnostic Trouble
Code Tests and Associated Procedures/Verification Tests and Procedures) after completing the diagnostic procedure.

*

Accessory Power Receptacle Replacement (HP2)   ()

*

Control Module References   (See: Testing and Inspection/Programming and Relearning) for control module replacement, setup, and programming