Glove Compartment Repair Procedures for Escalade V8 (2000)
Glove Compartment: Procedures
Instrument Panel (I/P) Compartment Replacement
REMOVAL PROCEDURE
1. Roll the instrument panel. Refer to IP Assembly - Rotating.
2. Remove the four nuts that retain the instrument panel compartment assembly to the carrier.
3. Remove the instrument panel compartment from the instrument panel.
4. Remove the distorted clips from the IP.
INSTALLATION PROCEDURE
1. Install the instrument panel compartment into the instrument panel.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the four nuts that retain the instrument panel compartment assembly to the carrier.
Tighten
Tighten the nuts to 10 N.m (89 lb in).
3. Roll the instrument panel back into place and secure. Refer to IP Assembly - Rotating.
Instrument Panel (I/P) Storage Compartment Replacement
REMOVAL PROCEDURE
1. Remove the IP storage compartment check strap.
2. Remove the IP storage compartment door.
3. Remove the IP storage compartment. Squeeze the compartment in order for the compartment to release.