cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Knock Sensor > < Initial Inspection and Diagnostic Overview|Page 5756
Page 3
background image

Schematic

CIRCUIT DESCRIPTION

The Class II Serial Data circuit to the Data Link Connector (DLC) allows bi-directional communication between the Vehicle Control Module (VCM)
and the scan tool. This is accomplished through pin 2 of the DLC. If communication between the scan tool and the VCM cannot be established, the
procedure in the DLC Diagnosis table should be used to diagnose the condition.

DIAGNOSTIC AIDS

Check for the following items:
^

For the VCM to establish communication with the scan tool, system voltage must be between 9.0 and 16.0 volts. If the system voltage is not
within this range, refer to Charging System Check in Starting and Charging for diagnosis.  See: Starting and Charging

^

Ensure that the correct application, such as model year, truckline, VIN code, has been selected on the scan tool.

An intermittent may be caused by any of the following conditions:
^

A poor connection

^

Rubbed through wire insulation

^

A broken wire inside the insulation

Thoroughly check any circuitry that is suspected of causing the intermittent complaint. Refer to Testing for Intermittent and Poor Connections in
Diagrams.

If a repair is necessary, refer to Wiring Repairs or Connector Repairs in Diagrams.

TEST DESCRIPTION

The numbers below refer to the step numbers on the diagnostic table.
2. This step determines if the scan tool is operating correctly.
6. This step monitors the actively communicating modules with the scan tool Diagnostic Circuit Check function. An active module is a module that is

successfully communicating on the Class 2 Serial Data line with the scan tool. An inactive module is a module which had previously established
communications with the scan tool, but currently is not communicating. If a module is not listed at all, then the module never successfully
established communications with the scan tool.

7. This step isolates the VCM by disconnecting all the other components on the Class 2 Serial Data circuit. After making repairs, it is necessary to

clear the DTCs from the modules that can communicate. Clearing the DTCs will avoid future misdiagnoses.

12. This step determines if the voltage is not available at the DLC due to an open battery feed fuse. If the fuse is open, determine if the open was due

to a short in the battery feed circuit before replacing the fuse.

Knock Sensor > < Initial Inspection and Diagnostic Overview|Page 5756