Escalade V8-5.7L VIN R (2000)
Catalytic Converter: Service and Repair
8600 Lb and Above
REMOVAL PROCEDURE
1. Raise and suitably support the vehicle.
2. Disconnect the oxygen sensor electrical connections.
3. Remove the nuts from the Y-pipe flat flange.
4. Remove the nuts, studs and flange seals from the Y-pipe and the exhaust manifold.