Escalade V8-5.7L VIN R (2000)
4. Remove the linear EGR valve.
5. Remove the flange gasket.
6. Clean the linear EGR valve gasket surface.
INSTALLATION PROCEDURE
1. Install the new flange gasket.
2. Install the linear EGR valve.
NOTE: Refer to Fastener Notice in Service Precautions.
3. Install the valve to flange bolts.
Tighten
3.1. Tighten the bolts the first time to 10 N.m (89 lb in.) each.
3.2. Tighten the bolts a final time to 25 N.m (18 lb ft) each.