Canister Vent Valve: Service and Repair
Evaporative Emission Canister Vent Solenoid Valve Replacement
Removal Procedure
Important: Clean all evaporative emission (EVAP) line connections and surrounding areas prior to disconnecting, in order to avoid possible
EVAP system contamination.
1. Raise and suitably support the vehicle. Refer to Lifting and Jacking the Vehicle (See: Maintenance/Vehicle Lifting/Service and Repair).
2. Disconnect the chassis wiring harness electrical connector (1) from the EVAP canister vent solenoid.
3. Disconnect the fuel fill pipe vent pipe quick connect fitting (2) from the EVAP canister vent solenoid. Refer to Plastic Collar Quick Connect
Fitting Service (See: Fuel Delivery and Air Induction/Fuel Line Coupler/Service and Repair/Plastic Collar Quick Connect Fitting Service).
4. Disconnect the EVAP canister vent solenoid line quick connect fitting (1) from the auxiliary EVAP canister. Refer to Plastic Collar Quick Connect
Fitting Service (See: Fuel Delivery and Air Induction/Fuel Line Coupler/Service and Repair/Plastic Collar Quick Connect Fitting Service).