OFF each time the rear window defogger switch is pressed.

‹› If the indicator does not turn ON or OFF with each switch press, replace the HVAC control module.

3. Command the Rear Defog Request ON and OFF with a scan tool. The rear window defogger should turn ON and OFF when changing between the

commanded states.

Circuit/System Testing

1. Ignition OFF, disconnect the REAR DEFOG relay.
2. Test for less than 1 ohm between the ground circuit terminal 85 and ground.

‹› If greater than the specified range, test the ground circuit for an open/high resistance.

3. Ignition ON, verify that a test lamp does not illuminate between the control circuit terminal 87 and ground. 

‹› If the test lamp illuminates, test the control circuit for a short to voltage. 

4. Verify that a test lamp illuminates between the B+ circuit terminal 30 and ground.

‹› If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.

5. Ignition OFF, disconnect the X2 harness connector at the defogger grid. 
6. Test for less than 1 ohm between the ground circuit terminal A and ground.

‹› If greater than the specified range, test the ground circuit for an open/high resistance.

7. Connect the harness connector at the defogger grid.
8. Ignition ON, connect a 30A fused jumper wire between the B+ circuit terminal 30 and the control circuit terminal 87. Verify the defogger grid is

activated.

‹› If the defogger grid does not activate, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, test or

replace the defogger grid.

9. Connect a test lamp between the control circuit terminal 86 and ground.

10. Command the defogger grid ON and OFF by pressing and depressing the rear defogger switch. The test lamp should turn ON and OFF when

changing between the commanded states.

‹› If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the HVAC control module. 
‹› If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the

HVAC control module.

11. If all circuits test normal, test or replace the REAR DEFOG relay.

Component Testing

Relay Test

1. Ignition OFF, disconnect the REAR DEFOGrelay.
2. Test for 60-180 ohms between terminals 85 and 86.

‹› If not within the specified range, replace the relay.

3. Test for infinite resistance between the following terminals:

*

30 and 86

*

30 and 87

*

30 and 85

*

85 and 87

‹› If not the specified value, replace the relay.

4. Install a 30-amp fused jumper wire between relay terminal 85 and 12 volts. Install a jumper wire between relay terminal 86 and ground. Test for

less than 2 ohms between terminals 30 and 87.

‹› If greater than the specified range, replace the relay.