6. Connect the other lead of the DMM to the other end of the circuit.
7. If the DMM displays low or no resistance, the circuit has good continuity.

With a Test Lamp

Note:  Only use the test lamp procedure on low impedance power and ground circuits.

1. Remove the power feed (i.e. fuse, control module) from the suspect circuit.
2. Disconnect the load.
3. Connect one lead of the test lamp to one end of the circuit to be tested.
4. Connect the other lead of the test lamp to battery positive voltage.
5. Connect the other end of the circuit to ground.
6. If the test lamp illuminates (full intensity), then the circuit has good continuity.

Testing for Electrical Intermittents

Testing for Electrical Intermittents

Danger:  This procedure should not be performed on high voltage circuits. Performing this procedure on high voltage circuits may result in
serious injury or death.

Special Tools

J 39200  Digital Multimeter

Perform the following procedures while wiggling the harness from side to side. Continue this at convenient points (about 6 inches apart) while watching
the test equipment.

*

Testing for Short to Ground   (See: Testing and Inspection/Component Tests and General Diagnostics)

*

Testing for Continuity   (See: Testing and Inspection/Component Tests and General Diagnostics)

*

Testing for a Short to Voltage   (See: Testing and Inspection/Component Tests and General Diagnostics)

If the fault is not identified, perform the procedure below using the MIN MAX feature on the J 39200   DMM. This feature allows you to manipulate the
circuit without having to watch the J 39200  . The J 39200   will generate an audible tone when a change is detected.

Note:  The J 39200   must be used in order to perform the following procedure since the J 39200   can monitor current, resistance or voltage while
recording the minimum (MIN), and maximum (MAX) values measured.

1. Connect the J 39200   to both sides of a suspected connector (still connected), or from one end of a suspected circuit to the other. Refer to

Troubleshooting with a Digital Multimeter   (See: Testing and Inspection/Component Tests and General Diagnostics) for information on
connecting the J 39200   to the circuit.

2. Set the rotary dial of the J 39200   to the V (AC) or V (DC) position.
3. Press the range button of the J 39200   in order to select the desired voltage range.
4. Press the MIN MAX button of the J 39200  . The J 39200   displays 100 ms RECORD and emits an audible tone (beep). 

Note:  The 100 ms RECORD mode is the length of time an input must stay at a new value in order to record the full change.

5. Simulate the condition that is potentially causing the intermittent connection, either by wiggling the connections or the wiring, test driving, or

performing other operations. Refer to Inducing Intermittent Fault Conditions   (See: Testing and Inspection/Component Tests and General
Diagnostics).

6. Listen for the audible Min Max Alert which indicates that a new minimum or maximum value has been recorded.
7. Press the MIN MAX button once in order to display the MAX value and note the value.
8. Press the MIN MAX button again in order to display the MIN value and note the value.
9. Determine the difference between the MIN and MAX values. 

*

If the variation between the recorded MIN and MAX voltage values is 1 volt or greater an intermittent open or high resistance condition exists.
Repair the condition as necessary.

*

If the variation between the recorded MIN and MAX voltage values is less than 1 volt an intermittent open or high resistance condition does
not exist.

Testing for Intermittent Conditions and Poor Connections