cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Exhaust System - Catalytic Converter Precautions|Page 3353 > < Exhaust System - Catalytic Converter Precautions|Page 3351
Page 2
background image

8. Remove the oxygen sensors if the catalytic converter is to be replaced.

Installation Procedure 

Notice:  Refer to Fastener Notice in Service Precautions.

1. If the catalytic converter was replaced, perform the following:

1.1.

Apply anti-seize compound GM P/N 12377953 or equivalent to the threads of the old oxygen sensors.

1.2.

Install the oxygen sensors.
Tighten the sensors to 42 Nm (31 ft. lbs.). 

2. Install a NEW exhaust seal to the exhaust manifold.
3. Install the catalytic converter. Slide the catalytic converter hanger into the exhaust pipe hanger bracket.

Exhaust System - Catalytic Converter Precautions|Page 3353 > < Exhaust System - Catalytic Converter Precautions|Page 3351