Escalade EXT AWD V8-6.2L (2009)
45. Connect the engine wiring harness electrical connector (4) to the MAP sensor.
46. Connect the engine harness electrical connector (2) to the EVAP canister purge solenoid.
47. Install the engine harness retainer to the stud and locator pin.
48. Install the engine harness retainer nut (1) and tighten to 5 Nm(44 lb in).
49. Install the generator. Refer to Generator Replacement (See: Starting and Charging/Charging System/Alternator/Service and Repair/Generator
Replacement).
50. Install the air cleaner outlet duct. Refer to Air Cleaner Resonator Outlet Duct Replacement (See: Tune-up and Engine Performance Checks/Air
Cleaner Housing/Air Cleaner Fresh Air Duct/Hose/Service and Repair).