Code Recording Procedure

1. Turn the main function switch to the CODE position.

Note:  
*

If power is interrupted prior to the recording of the seven-character code, the code will be lost and the flow rate test will need to be repeated.

*

The flow test must run for a minimum of 8-10 seconds and be above 0.5 GPM for a code to be generated.

2. Record TESTED flow rate, temperature, cycle and seven-character flow code information on repair order.

Clean-up

1. Turn the main function switch (2) to the IDLE position and allow the supply vessel pressure to dissipate.
2. Turn the main power switch (1) to the OFF position.

Note:  A small amount of water may drain from the bottom of the unit when the air supply is disconnected. This is a normal operation of the
built-in water separator.