cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

All Technical Service Bulletins: > < Blower Motor Runs Continuously|Page 2769
Page 1
background image

Blower Motor Switch: Customer Interest
A/C - No Low Blower Operation

Bulletin No. T     

88-14

File in Group

1

Number

40

Corp. Ref. No. 711209
Date

Sept. '87

SUBJECT:

NO LOW BLOWER OPERATION

MODELS AFFECTED: 1981-1987 REAR-WHEEL-DRIVE DE VILLE AND BROUGHAM 1980-1985 ELDORADO AND SEVILLE

Some 1981-1987 RWD De Villes and Broughams, and 1980-1985 Eldorados and Sevilles equipped with a non-BCM controlled ECC system may
experience a condition of no low blower operation. This condition may be caused by a crossfeed on circuit 976. Confirm a no low blower condition by
selecting the low setting on the ECC head and checking the voltage across the blower motor terminals. If this voltage is above 6 volts, the ECC system is
not achieving low blower operation. Repair this condition using the following procedure:

1.

Cut circuit 976 on both sides of the center bulkhead connector (C101).

2.

Run a jumper wire through an open connector cavity.

3.

Splice the harness wiring to this jumper on both sides of the bulkhead connector.

For warranty purposes, use Labor Operation N6030 at .5 hour.

All Technical Service Bulletins: > < Blower Motor Runs Continuously|Page 2769