cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

02-07-30-052G|Page 3700 > < 02-07-30-052G|Page 3698
Page 2
background image

IMPORTANT:

DO NOT SUBSTITUTE WITH ANY OTHER SOLUTION. THE FLUSHING TOOL IS DESIGNED TO USE ONLY THIS
CONCENTRATE. USE OF ANY OTHER SOLUTION CAN RESULT IN DAMAGE TO THE TOOL, COOLER COMPONENTS,
OR IMPROPER FLUSHING OF THE COOLER.

3.

Secure fill cap and pressurize the flusher can with shop air to 550-700 kPa (80-100 psi).

CAUTION: Shop air supply must be equipped with a water/oil filter and regulated to 825 kPa (120 psi).
4.

Connect the discharge hose to the transmission end of the oil cooler return pipe which is attached to the top fitting of the radiator oil cooler. (See
Table 1: for location.)

Table 1: Direction of Fluid in Oil Cooler Pipes at Transmission/Transaxle

Top connector is cooler feed

Vertical (top) connector is cooler feed

Bottom connector is cooler return

Horizontal (bottom) connector is cooler return

200C

440-T4

200-4R

Top connector is cooler return Bottom connector is cooler feed

125C

350C
400

325/325-4L

5.

Clip discharge hose onto an oil drain container.

6.

Mount the flushing tool to undercarriage of vehicle with the hook provided and connect the feed hose from the flushing tool to the remaining oil
cooler pipe.

7.

With the tool water valve in the "OFF" position, connect the water hose to the water supply.

8.

Turn on the water supply at the faucet.

Initial Flush

9.

Switch tool water valve to the "ON" position and allow the water to flow through the oil cooler for 10 seconds to remove the supply of
transmission fluid in the system.

NOTICE:

If water does not flow through the oil cooler (system is completely plugged) do not continue flushing procedure. Turn the water off
immediately and inspect the pipes and cooler for restriction. Replace the oil pipe(s) and/or cooler following the procedure in the appropriate
Service Information Manual.

10.

Switch tool water valve to the "OFF" position and clip the discharge hose onto a five gallon pail with a lid or position a shop towel over the end of
the discharge hose to prevent splash. Discharge will foam vigorously when solution is introduced into water stream.

11.

Switch tool water valve to the "ON" position and depress the trigger to mix flushing solution into the water flow. Use the bale clip provided on the
handle to hold the trigger down.

12.

Flush oil cooler with water and solution for two minutes. During this flush, attach the air supply to the air valve for 3 to 5 seconds at the end of
every 15-20 second interval to create a surging action.

CAUTION: Shop air supply must be equipped with a water/oil filter and regulated to 825 kPa (120 psi).

13.

Release the trigger and switch the tool water valve to the "OFF" position.

14.

Disconnect both hoses from the oil cooler pipes.

Backflush

15.

Connect hoses to the opposite oil cooler pipes from the initial flush procedures to perform a backflush.

16.

Repeat steps 11 and 12.

17.

Release the trigger and allow water to rinse the oil cooler for one minute only.

18.

Switch tool water valve to the "OFF" position and turn the water supply off at the faucet.

02-07-30-052G|Page 3700 > < 02-07-30-052G|Page 3698