Radiator Cooling Fan Motor Relay: Customer Interest
Cooling System - Fans On After Ignition Off

Bulletin No.: T-92-2
File in Group: 6
Number: 10
Corp. Ref. No.: 006201
Date: Sept. 1991

SUBJECT:
INTERMITTENT DEAD BATTERY OR COOLING FANS REMAINING ON AFTER IGNITION OFF

MODELS AFFECTED:
1988-1990 DE VILLES AND FLEETWOODS

This bulletin supersedes Service bulletin T-90-19, dated 11/89 which should be discarded.

Some 1988-1990 DeVilles and Fleetwoods may experience an intermittent dead battery or cooling fans remaining on after the ignition is turned off. This
may be caused by one of the cooling fan relay contacts welding together. To correct this condition install cooling fan relays, P/N 25553347, which uses
silver-tin oxide contacts to reduce contact welding. A new fan relay bracket, P/N 25558149, must also be installed to accommodate the new style relay
due to the different size retaining slot on the relay case.

Parts are currently available from GMSPO.

For warranty purposes use Labor Operation T5204 at .2 hour.