cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

All Technical Service Bulletins for Evaporator Core:|911204A|Page 5303 > < All Technical Service Bulletins for Evaporator Core:|911204A|Page 5301
Page 4
background image

9.

Position pedestal fan as show in Figure 2 and turn on high to provide cross ventilation during cleaning procedure.

10.

Use Kent - Moore tool J - 36645, or equivalent, siphon - type parts cleaning spray can capable of delivering two ounces per minute of liquid when
driven wit shop air at 80-90 psi. Insert the nozzle of the spray gun through the power module opening and insert the siphon hose into container of
disinfectant. Take care to place the bottle of disinfectant in a secure, upright position to avoid spilling the contents. Direct spray toward evaporator
face taking extra care to ensure adequate coverage of the corners and edges, completely saturating the entire core. Use the entire container of
solution.

CAUTION:

Do not allow disinfectant to come in contact with hot engine components such as the exhaust manifold as this may result in toxic fumes.

11.

Reach into the vehicle and turn the ignition to the off position, and allow the core to soak for five minutes.

12.

Reach into vehicle and start engine.

13.

Thoroughly rinse the evaporator core with one quart of clean water using the spray gun to rinse any disinfectant residue.

14.

Reach into the vehicle and turn the ignition to the off position and then reinstall power module.

CAUTION:

Care should be taken in handling the power module to prevent burns or personal injury from the heat sink which may be hot.

15.

Dispose of disinfectant and rinse water runoff collected in drain pan into a sanitary drain system.

16.

Disconnect battery charger.

Procedure C (Install Afterblow Module, P/N 25533406)

The installation of the afterblow module as outlined in the following steps will turn the blower motor on approximately 50 minutes after the vehicle
ignition is turned off if the compressor was engaged for more than four minutes during the last ignition cycle. During the first 50 minutes after the vehicle
ignition is turned off, the evaporator will accumulate water condensate on the core. Cycling the blower motor at high speed for approximately five
minutes will force the water to be shed from the core and to drain from the evaporator case. This procedure is used to prevent the recurrence of the odor.
Be sure to advise the owner of this change in operation.

1.

If vehicle is equipped with Passenger Side Air Bag (1993 Eldorado/Seville), refer to the appropriate Service Information Manual and follow the
procedure to disable the SIR.

2.

Remove close out panel(s) and glove box as required to gain access to the circuits shown in the attached applicable wiring diagram. Refer to the
appropriate Service Information Manual for component location and service procedures.

All Technical Service Bulletins for Evaporator Core:|911204A|Page 5303 > < All Technical Service Bulletins for Evaporator Core:|911204A|Page 5301