Seville STS V8-4.6L VIN 9 (1998)
Loss Of Class 2 Serial Data DTC
Loss Of Class 2 Serial Data DTC
LOSS OF CLASS 2 SERIAL DATA DTC
LOSS OF CLASS 2 SERIAL DATA DTCS MATRIX
The above charts represent a complete matrix of all Loss of Class 2 Serial Data DTCs. Use these charts as follows:
^
The top row of each chart indicates which module has lost Class 2 communications.
^
The left column of each chart indicates which module observed this Loss of Class 2 Serial Data, and internally set a DTC to identify this
condition.
SIMPLE BUS INTERFACE (SBI) SERIAL DATA LINE
The Simple Bus Interface is used for serial data communication between the four door modules as well as the LH Front Power Window Switch.
Electrical input and output devices within the doors are wired to the corresponding door modules; the power door locks, power windows, power
mirrors, jamb switches, and cylinder switches are all controlled this way.