cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

03-01-39-006B|Page 278 > < Air Conditioning Programmer (ACM)|Page 271
Page 1
background image

Instrument Panel Control Module: Customer Interest
A/C - Hard To Maintain Temp/Blower Motor Noisy

Bulletin No.: 03-01-39-006B

Date: October 19, 2006

TECHNICAL

Subject:
Difficult to Maintain Desired HVAC Temperature, HVAC Blower Noisy (Update HVAC Calibrations with Tech 2(R))

Models:
1998-2003 Cadillac Seville
2000-2004 Cadillac DeVille
2001-2004 Buick LeSabre
2001-2004 Pontiac Bonneville

with Automatic HVAC (RPOs CJ2 or C68)

Supercede:

This bulletin is being revised to update the models information with a statement that the bulletin only applies to vehicles with automatic HVAC. Please
discard Corporate Bulletin Number 03-01-39-006A (Section 01 - HVAC).

Built Prior to the Breakpoint Dates shown.

Condition

Some customers may comment that it is difficult to maintain the desired HVAC temperature. The HVAC system over shoots the desired temperature and
blows air that transitions from too hot, to too cold, onto the occupants. The system does settle into the desired temperature after a period of searching.
The blower may be noisy and the fan runs at a speed higher than desired. It has also been found that the HVAC system may cycle rapidly between air
delivery modes (for example, floor to bi-level to floor).

Correction

A procedure using the Tech 2(R) has been developed to update the Instrument Panel Module (IPM) calibrations for all vehicles listed above. 

In addition to the IPM update, the Seville and DeVille models MUST also perform an update to the HVAC calibration within the Dash Integration
Module (DIM). Use the following procedures.

The Tech 2(R) must contain the NAO software version 25.001 or later.

For All Vehicles

Install the Tech 2(R) to the vehicle and power on.

Select "Diagnostic" from the menu.

Build the vehicle from the menu options.

Select "Body" from the menu.

Build the vehicle from the menu options.