32. Strip 13 mm (0.5 in) of insulation from each of the pretensioner connector wire leads.
33. Cut two 6.1 m (20 ft) deployment wires from a 0.8 mm (18 gage) or thicker multi-strand wire. Use these wires to fabricate the deployment harness
34. Strip 13 mm (0.5 in) of insulation from both ends of the wires cut in the previous step.
35. Twist together one end from each of the wires in order to short the wires. Deployment wires shall remain shorted, and not connected to a power
source until you are ready to deploy the pretensioner.
36. Twist together one connector wire lead to one deployment wire.