9. Notice:  Refer to Torque Reaction Against Timing Drive Chain Notice in Service Precautions.

Use an open end wrench on the hex cast into the left exhaust camshaft to prevent the camshaft from rotating when loosening the camshaft oil
control valve.

10. Loosen and remove the left exhaust oil control valve (8).

Installation Procedure 