SRX 2WD V8-4.6L VIN A (2004)
10. Remove the condenser tube bolt.
11. Disconnect the condenser tube from the condenser.
12. Remove and discard the O-ring.
13. Disconnect the high pressure sensor electrical connector.
14. Remove the condenser tube.
15. Remove the high pressure sensor.
INSTALLATION PROCEDURE
NOTE: Refer to Fastener Notice in Service Precautions.
1. Install the high pressure sensor.
Tighten
Tighten the sensor to 9.8 N.m (87 lb in).
2. Install the condenser tube.
3. Connect the high pressure sensor electrical connector.
4. Install a new O-ring to the condenser tube.
5. Connect the condenser tube to the condenser.
6. Install the condenser tube bolt.
Tighten
Tighten the sensor to 9 N.m (80 lb in).