cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Camshaft Position (CMP) Actuator Replacement - Bank 2 (Left) Exhaust|Page 4766 > < Camshaft Position (CMP) Actuator Replacement - Bank 2 (Left) Exhaust|Page 4764
Page 26
background image

1. Install the oil control valve through the opening in the right exhaust camshaft position actuator and thread it into the right exhaust camshaft.

2. Ensure both camshaft actuator timing marks (1, 3) are aligned with the paint marks on the secondary timing chain previously created.

Camshaft Position (CMP) Actuator Replacement - Bank 2 (Left) Exhaust|Page 4766 > < Camshaft Position (CMP) Actuator Replacement - Bank 2 (Left) Exhaust|Page 4764