SRX AWD V6-3.0L (2010)
Positive: Service and Repair
Auxiliary Battery Positive Cable Replacement
Auxiliary Battery Positive Cable Replacement
Removal Procedure
1. Remove the battery fuse block cover (1).
2. Disconnect the negative battery cable.Refer to Battery Negative Cable Disconnection and Connection (See: Negative/Service and Repair/Battery
Negative Cable Disconnection and Connection)
3. Remove the auxiliary battery positive terminal nut (2) from the fuse block.
4. Remove the nut (1) from the rear of the generator
5. Remove the nut (2) from the starter solenoid.
6. Remove the auxiliary battery positive cable from the vehicle.