Twisted/shielded cable is used in order to protect wiring from electrical noise. Two-conductor cable of this construction is used between the radio and
the Delco-Bose(R) speaker/amplifier units and other applications where low level, sensitive signals must be carried. Follow the instructions below in
order to repair the twisted/shielded cable.

1. Remove the outer jacket (1). Use care not to cut into the drain wire of the mylar tape.
2. Unwrap the tape. Do not remove the tape. Use the tape in order to rewrap the twisted conductors after the splice is made.

3. Prepare the splice. Untwist the conductors and follow the instructions for Splicing Copper Wire Using Splice Sleeves   (See: Testing and

Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring Repairs/Splicing Copper Wire Using
Splice Sleeves). Staggering the splices by 65 mm (2.5 in) is recommended.

Note:  Apply the mylar tape with the aluminum side inward. This ensures good electrical contact with the drain wire.

4. Re-assemble the cable.

*

Rewrap the conductors with the mylar tape. If the mylar tape is damaged, use 3M product AL-36FR to replace the damaged mylar tape.

*

Use caution not to wrap the drain wire in the tape (1).

*

Follow the splicing instructions for copper wire and splice the drain wire.

*

Wrap the drain wire around the conductors and tape with electrical tape to replace the outer insulation.

5. Tape over the entire cable. Use a winding motion when you apply the tape.

Wiring Repairs

Wiring Repairs

The Wiring Repairs section contains the following types of wiring repair information. Using these elements together will make wiring repair faster and
easier:

*

Testing for Intermittent Conditions and Poor Connections   (See: Testing and Inspection/Component Tests and General Diagnostics/General
Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)

*

Flat Wire Repairs   (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring
Repairs/Flat Wire Repairs)

*

GMLAN Wiring Repairs   (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Wiring Repairs/GMLAN Wiring Repairs)

*

High Temperature Wiring Repairs   (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Wiring Repairs/High Temperature Wiring Repairs)

*

Heated Oxygen Sensor Wiring Repairs   (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Wiring Repairs/Heated Oxygen Sensor Wiring Repairs)

*

Splicing Copper Wire Using Splice Sleeves   (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical
Diagnostic Procedures/Wiring Repairs/Splicing Copper Wire Using Splice Sleeves)