SRX AWD V6-3.0L (2010)
Relay Test
1. Ignition OFF, disconnect the KR5 rear defogger relay.
2. Test for 60-180 ohm between terminals 85 and 86.
‹› If not within the specified range, replace the KR5 rear defogger relay.
3. Test for infinite resistance between the following terminals:
*
30 and 86
*
30 and 87
*
30 and 85
*
85 and 87
‹› If not the specified value, replace the KR5 rear defogger relay.
4. Install a 25 A fused jumper wire between relay terminal 86 and 12 V. Install a jumper wire between relay terminal 85 and ground. Test for less
than 2 ohm between terminals 30 and 87.
‹› If greater than the specified range, replace the KR5 rear defogger relay.
Repair Instructions
Perform the Diagnostic Repair Verification (See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Diagnostic Trouble
Code Tests and Associated Procedures/Verification Tests and Procedures) after completing the diagnostic procedure.
*
Liftgate Window Replacement (See: Windows/Window Glass/Liftgate Window Glass/Service and Repair)
*
Relay Replacement (Attached to Wire Harness) (See: Power and Ground Distribution/Power Distribution Relay/Service and Repair/Relay
Replacement (Attached to Wire Harness))Relay Replacement (Within an Electrical Center) (See: Power and Ground Distribution/Power
Distribution Relay/Service and Repair/Relay Replacement (Within an Electrical Center))
*
Control Module References (See: Testing and Inspection/Programming and Relearning) for HVAC control module and HVAC control
replacement, setup, and programming