1. Remove the right intake camshaft position actuator oil control valve (2).
2. Pull the actuator forward to disengage the actuator from the camshaft alignment pin.
3. Disengage the secondary timing chain from the actuator and remove the actuator.
4. Clean and inspect the camshaft timing drive components.

Installation Procedure 

1. Locate the camshaft alignment pin hole (2) on the back of the actuator. This hole will mate with the camshaft alignment pin.