5. Install the evaporator tube to the strut tower retaining clip.
6. Connect the liquid line to the condenser tube.
7. Install the liquid line to condenser tube quick connect fitting.
8. Gently tug on the liquid line to ensure that the clamp is engaged.
9. Install the air cleaner intake duct to the vehicle.
10. Evacuate and recharge the refrigerant. Refer to Refrigerant Recovery and Recharging.
11. Leak test the fittings of the repaired or reinstalled component using J39400-A.
Liquid Line Replacement (With RPO Code C57)
LIQUID LINE REPLACEMENT (WITH RPO CODE C57)
TOOLS REQUIRED
-
J 39400-A Halogen Leak Detector
-
J 45689 A/C Quick Connect Joint Tool
REMOVAL PROCEDURE