cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Recall 05V024000: Inadvertent Air Bag Deployment|Page 10277 > < Recall 05V024000: Inadvertent Air Bag Deployment|Page 10275
Page 1
background image

Inflatable Restraint Sensing And Diagnostic Module: Service and Repair

INFLATABLE RESTRAINT SENSING AND DIAGNOSTIC MODULE REPLACEMENT

REMOVAL PROCEDURE

CAUTION:
-

Do not strike or jolt the inflatable restraint sensing and diagnostic module (SDM). Before applying power to the SDM, make sure that it is
securely fastened with the arrow facing toward the front of the vehicle. Failure to observe the correct installation procedure could cause
SIR deployment, personal injury, or unnecessary SIR system repairs.

-

If the vehicle interior is exposed to moisture and becomes soaked up to the level of the sensing and diagnostic module (SDM), the SDM
and SDM harness connector must be replaced. The SDM could be activated when powered, which could cause airbag deployment and
result in personal injury.

-

Refer to SIR Caution in Service Precautions.

1. Disable the SIR system. Refer to SIR Disabling and Enabling Zone 8.
2. Remove the center console.

3. Remove the connector position assurance (CPA) (1) from the wiring harness

connector (2) to the inflatable restraint sensing and diagnostic module (SDM).

4. Push the flex lock button (3) down and move the sliding connector locking cover (4) to the OPEN position.

IMPORTANT: The SDM is shown with the carpet removed for illustration purposes only. Removal of the front carpet or the front seats is not
necessary to service the SDM.

5. Disconnect the wiring harness connector from the SDM (1).
6. Remove the SDM mounting fasteners (2).

Recall 05V024000: Inadvertent Air Bag Deployment|Page 10277 > < Recall 05V024000: Inadvertent Air Bag Deployment|Page 10275