cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Camshaft Position (CMP) Actuator Replacement - Bank 2 (Left) Exhaust|Page 3488 > < Camshaft Position (CMP) Actuator Replacement - Bank 2 (Left) Exhaust|Page 3486
Page 22
background image

Notice:  Refer to Fastener Notice in Service Precautions.

2. Ensure both camshaft actuator timing marks (1, 3) are aligned with the paint marks on the secondary timing chain previously created.

3. Use an open end wrench on the hex cast into the right intake camshaft to prevent the camshaft from rotating when tightening the camshaft oil

control valve.
Tighten the camshaft oil control valve to 120 Nm (89 ft. lbs.).

Notice:  Refer to Torque Reaction Against Timing Drive Chain Notice in Service Precautions.

Camshaft Position (CMP) Actuator Replacement - Bank 2 (Left) Exhaust|Page 3488 > < Camshaft Position (CMP) Actuator Replacement - Bank 2 (Left) Exhaust|Page 3486