4. Re-assemble the cable.

-

Rewrap the conductors with the mylar tape.

-

Use caution not to wrap the drain wire in the tape (1).

-

Follow the splicing instructions for copper wire and splice the drain wire.

-

Wrap the drain wire around the conductors and tape with mylar tape.

IMPORTANT:  Apply the mylar tape with the aluminum side inward. This ensures good electrical contact with the drain wire.

5. Tape over the entire cable. Use a winding motion when you apply the tape.