Information Bus: Testing and Inspection
Scan Tool Does Not Communicate with Keyword Data Line

SCAN TOOL DOES NOT COMMUNICATE WITH KEYWORD DATA LINE

CIRCUIT DESCRIPTION

The Keyword protocol utilizes a single wire bi-directional data line between the modules and the scan tool. The message structure is a request and
response arrangement. Keyword serial data is used for scan tool diagnostics only. The modules do not exchange data on this circuit.

The following modules are connected to the Keyword serial data circuit:
-

Headlamp - Left w/export

-

Headlamp - Right w/export

TEST