TERMINAL REPAIR PROCEDURE

Use the appropriate terminal and crimper in the J-38125 in order to replace the terminal.

Weather Pack Connectors

WEATHER PACK CONNECTORS

The following is the proper procedure for the repair of Weather Pack(R) Connectors.

1. Separate the connector halves (1).
2. Open the secondary lock. A secondary lock aids in terminal retention and is usually molded to the connector (1).
3. Grasp the wire and push the terminal to the forward most position. Hold the wire in this position.

4. Insert the Weather Pack(R) terminal removal tool into the front (mating end) of the connector cavity until it rests on the cavity shoulder (1).
5. Gently pull on the wire to remove the terminal through the back of the connector (2).

IMPORTANT:  Never use force to remove a terminal from a connector.

6. Inspect the terminal and connector for damage. Repair as necessary.
7. Reform the lock tang (2) and reset terminal in connector body.
8. Close secondary locks and join connector halves.
9. Verify that circuit is complete and working satisfactorily.

10. Perform system check.

Circuit Protection - Circuit Breakers

CIRCUIT PROTECTION - CIRCUIT BREAKERS

A circuit breaker is a protective device that is designed to open the circuit when a current load is in excess of the rated breaker capacity. If there is a short
or other type of overload condition in the circuit, the excessive current will open the circuit between the circuit breaker terminals. Two types of circuit
breakers are used.

Circuit Breaker
This type opens when excessive current passes through it for a period of time. It closes again after a few seconds, and if the cause of the high current is
still present, it will open again. The circuit breaker will continue to cycle open and closed until the condition causing the high current is removed.

Positive Temperature Coefficient (PTC) Circuit Breaker
This type greatly increases its resistance when excessive current passes through it. The excessive current heats the PTC device, as the device heats its
resistance increases. Eventually the resistance gets so high that the circuit is effectively open. Unlike the ordinary circuit breaker the PTC unit will not
reset until the circuit is opened, by removing the voltage from its terminals. Once the voltage is removed the circuit breaker will re-close within a
second or 2.

Circuit Protection - Fuses

Diagram Information and Instructions|Page 8664 > < Diagram Information and Instructions|Page 8662