2. Connect the low coolant sensor electrical connector.
Notice: Refer to Fastener Notice in Service Precautions.
3. Install the surge tank nut.
Tighten the nut to 9 N.m (80 lb in).
4. Install the surge tank bolt.
Tighten the bolt to 9 N.m (80 lb in).
Important: Lubricate the inside diameters of the hoses with clean coolant prior to installation.
5. Connect the surge tank inlet hose to the surge tank.
6. Using the J 38185, reposition the hose clamp to secure the surge tank inlet hose.
7. Connect the surge tank outlet hose.
8. Using the J 38185, reposition the hose clamp to secure the surge tank outlet hose.
9. Connect the master cylinder fluid level sensor electrical connector.
10. Fill the cooling system.