cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake|Page 8642 > < Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake
Page 2
background image

2.  Install the CMP actuator valve.

Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners
requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use
paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint
clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid
damage to parts and systems.

3.  Install the CMP actuator valve bolt.

Tighten the CMP actuator valve bolt to 10 Nm (89 lb in).

4.  Connect the CMP actuator valve electrical connector.

5.  Install the front compartment sight shields as necessary.

Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake|Page 8642 > < Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake