cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Camshaft Position Actuator Solenoid Replacement - Bank 1 (Right Side) Intake|Page 4947 > < Camshaft Position Actuator Solenoid Replacement - Bank 1 (Right Side) Intake|Page 4945
Page 1
background image

Variable Valve Timing Solenoid: Service and Repair
Camshaft Position Actuator Solenoid Replacement - Bank 2 (Left Side) Exhaust

CAMSHAFT POSITION ACTUATOR SOLENOID REPLACEMENT - BANK 2 (LEFT SIDE) EXHAUST

REMOVAL PROCEDURE

1. Remove the remote power steering reservoir.
2. Disconnect the actuator solenoid electrical connector.
3. Remove the left exhaust camshaft position (CMP) actuator solenoid bolts.
4. Remove the left exhaust CMP actuator solenoid.

INSTALLATION PROCEDURE

IMPORTANT:  The CMP actuator solenoid must be precisely aligned to the CMP actuator oil control valve on the end of the camshaft. This is
accomplished with an alignment pin. Failure to align the CMP actuator solenoid to the CMP actuator oil control valve can lead to poor engine
performance and engine component damage.

To allow for CMP actuator solenoid to CMP actuator oil control valve alignment, DO NOT install the NEW CMP actuator solenoid alignment plugs
at this time.

CAMSHAFT POSITION ACTUATOR SOLENOID ALIGNMENT PROCEDURE

1. Make an alignment pin from drill rod 15/64 inch diameter and at least 50 mm (1.97 in) long.
2. Verify that the alignment pin will pass through the CMP actuator solenoid alignment hole.
3. Verify that the alignment pin will fit into the alignment hole in the CMP actuator oil control valve.
4. Apply a 2 mm (0.079 in) bead of RTV GM P/N 12378521 (Canadian P/N 88901148) around the flange of the CMP actuator solenoid.
5. Install the CMP actuator solenoid over the oil control valve.

Camshaft Position Actuator Solenoid Replacement - Bank 1 (Right Side) Intake|Page 4947 > < Camshaft Position Actuator Solenoid Replacement - Bank 1 (Right Side) Intake|Page 4945