cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Camshaft Position (CMP) Actuator Replacement - Bank 2 (Left) Exhaust|Page 5451 > < Camshaft Position (CMP) Actuator Replacement - Bank 2 (Left) Exhaust|Page 5449
Page 22
background image

Install the oil control valve through the opening in the right intake camshaft position actuator and thread it into the right intake camshaft.

2. Ensure both camshaft actuator timing marks (1, 3) are aligned with the paint marks on the secondary timing chain previously created.

3. Notice:  Refer to Torque Reaction Against Timing Drive Chain Notice in Service Precautions.

Use an open end wrench on the hex cast into the right intake camshaft to prevent the camshaft from rotating when tightening the camshaft oil
control valve.
^

Tighten the camshaft oil control valve to 120 Nm (89 ft. lbs.).

Camshaft Position (CMP) Actuator Replacement - Bank 2 (Left) Exhaust|Page 5451 > < Camshaft Position (CMP) Actuator Replacement - Bank 2 (Left) Exhaust|Page 5449