STS AWD V8-4.6L VIN A (2006)
Expansion Valve: Service and Repair
THERMAL EXPANSION VALVE REPLACEMENT
TOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Remove the instrument panel (I/P) carrier.
2. Remove the insulation (1) from the thermal expansion valve (TXV). Discard the used insulation.
3. Remove the HVAC line clamp screw.
4. Remove the HVAC line clamp.
5. Remove the bolts (1) that secure the TXV to the evaporator.